UL listed 12v 24v Triac dimmable led driver are our competitive product.dimmable led power supply have high efficiency,high reliability,save energy Through 100% full load burn-in test. It application with indoor & outdoor illuminating lights.
Specification
model
SMT-012-060VTHW
SMT-024-060VTHW
Output
DC Voltage
12V
24V
Voltage Accuracy
±0.5V
±0.5V
Voltage Regulation
±0.5%
Rated current
5.00A
2.50A
Load Regulation
±1%
Rated power
60W
60W
Input
Voltage Range
100-277V AC
Frequency Range
47~63HZ
Power Factor ( Typ.)
0.98@120VAC 0.95@277VAC
0.98@120VAC 0.95@277VAC
Full Load Efficiency(Typ.)
>82%
>83%
AC Current(Typ.)
0.9A/110VAC
Inrush Current (Typ.)
14A, 50%, 780us
Leakage current
<0.50mA
Over temperature
100℃±10℃ shut down o/p voltage, automatically recover after cooling.
Short Circuit
shut down o/p voltage, re-power on to recover after fault condition removed
Over Loading
≤120% Hiccup mode,recovers automatically after fault condition is removed
Over voltage
≦140VAC(90~135V) , ≦285VAC(170~277V)
Environment
Working TEMP.
-40~+60℃
Working Humidity
20~90%RH,non-condensing
Storage TEM.,Humidity
-40~+80℃,10~95%RH
TEMP.coefficient
±0.03%/℃(0~50℃)
Vibration
10~500Hz,2G 10min./1 cycle,period for 60min.each along X,Y,Z axes
Safety&EMC
Safety standards
UL8750+UL1310
Withstand voltage
I/P-O/P:3.75KVAC
Isolation resistance
I/P-O/P:100MΩ/500VDC/25℃/70%RH
EMC EMISSION
FCC Part 15 B
EMC IMMUNITY
Compliance to EN55015; EN61000-4-2,3,4,5,6,8,11, EN61547
Alight industry level (surge4KV)
Others
Weight
About 0.35Kg
Size
178*61*24mm(L*W*H)
packing
20PCS/CTN
Notes
1. All parameters NOT specially mentioned are measured at 110V/277VAC input , rated load and
25℃of ambient temperature.
2. Ripple& noise are measured at 20MHz of bandwidth by using a 12”twisted
pair-wire terminated with a 0.1uf &47uf parallel capacitor.
3. Tolerance:includes set us tolerance,line regulation and load regulation .
Label
Mechanical Specification
Input terminals "Black" and "White" to connect to AC L and N.
Output terminals "Red" to LED Positive side (+) , "Black" to LED Negative side (-).
Dimming Operation
Output constant current level can be adjusted through input terminal of the AC phase line(L) by connection a triac dimmer.
Compatible with Leading edge or trailing edge triac dimmers, but trailing edge dimmers work better..
Please try to use dimmers with power at least 1.5 times as the output power of the driver.
Derating Curve