CE ETL ROHS listed triac PWM constant current LED lighting driver
The choice of constant current LED lighting driver the world's major fixture manufacturers, Smarts high-efficiency LED drivers last as long as the LEDs in your fixture design. Smarts LED drivers meet or exceed worldwide efficiency standards and provide the most cost effective and safety conscious power solution for lighting fixtures.
Specification
Model
SMT-115-0700CT
SMT-090-0900CT
SMT-080-1050CT
SMT-067-1200CT
Output
DC Current
700mA
900mA
1050mA
1200mA
Current Accuracy
±5%
Voltage Range
80-115V
70-90V
55-80V
40-67V
Rated power
80W
80W
80W
80W
Input
Voltage Range
90-130VAC / 170~250VAC
Frequency Range
47~63HZ
Power Factor (Typ.)
PF≧0.93/110V ; PF≧0.95/220V ; PF≧0.94/250V
Full Load Efficiency(Typ.)
>85%
>85%
>85%
>85%
AC Current(Typ.)
0.14A/110VAC 0.12 A/220VAC 0.01A/250VAC
Leakage current
<0.27mA/110VAC; ﹤0.25mA/220VAC
Protection
Short Circuit
Hiccup mode, recovers automatically after fault condition is removed.
Over voltage
≦270VAC
Environment
Working TEMP.
-40~+60℃
Working Humidity
20~90%RH,non-condensing
Storage TEM.,Humidity
-40~+80℃,10~95%RH
TEMP.coefficient
±0.03%/℃(0~50℃)
Vibration
10~500Hz,2G 10min./1 cycle,period for 60min.each along X,Y,Z axes
Safety&EMC
Safety standards
EN-60950-1, EN-61347-1-2
Withstand voltage
I/P-O/P:3.75KVAC
Isolation resistance
I/P-O/P:100MΩ/500VDC/25℃/70%RH
EMC EMISSION
Compliance toEN55015,EN61000-3-2 (≧50%load)
EMC IMMUNITY
Compliance to EN55015,EN61000-4-2,3,4,5,6,8,11,A light industry level (surge4KV)
Others
Weight
0.34Kg/pcs
Size
200*68*45mm(L*W*H)
packing
324*298*176mm
Notes
1. All parameters NOT specially mentioned are measured at 110V/230VAC input , rated load and
25℃of ambient temperature.
2. Ripple& noise are measured at 20MHz of bandwidth by using a 12”twisted pair-wire terminated with a
0.1uf &47uf parallel capacitor.
3. Tolerance:includes set us tolerance,line regulation and load regulation .
Physical size
l Input power cord: AC (L), (N), and earth wire (G)
l Output Red is(DIM+),Black is(DIM-)
Dimming Operation
1. Output constant current level can be adjusted through input terminal of the AC phase line(L) by connection a triac dimmer.
2. Compatible with Leading edge or tailing edge triac dimmers.
3. please try to use the small power dimmers, which can be accessed to a wider dimming range, high-power dimmer is difficult to achieve the output current to zero.
Connection diagram
Derating Curve
FAQ
1. I tested the magnitude magnetic driver and it runs the LEDs to hot. Does the one you offer run the LEDs like a switching power source and is dimable with a triac dimmer?
Answer: Yes, all our led drivers run the leds like switching power source and this led driver you've mentioned is triac dimmable type, it should be dimmable with a triac dimmer.
2.What is UL annual fees?
Answer: UL annual fees will be charged by UL for once time each year. Its funtion is maintaining cost for the online UL file.
Actually, it's necessary for you to pay UL multiple listee cost and UL annual fees to UL if you would like to do UL multiple listing. And all the cost would be charged by UL directly.
3.Do these(vt) buzz working with forward edge dimming?
Answer: Actually, we sugguest that our customers usel with forward edge triac dimmer for our 100-130vac VT series. And they work well with forward edge triac dimmer.
Most importantly, there is almost no any buzz during they work with forward edge triac dimmer.