SCR dimmers are widely used in the dimming system, but many users have encountered SCR be damaged when using phase cut dimming power supply. The following are 4 common causes of the SCR dimmer damage.
---Voltage breakdown. The SCR is damaged by the inability to withstand the voltage, there is a hole in the chip, which sometimes can be seen with a magnifying glass. The reason may be that the tube itself has voltage drop or high voltage breakdown when the power supply circuit is disconnected.
----Current damage. A characteristic of current damage is that the chip is fired into a pit and its position is away from the control pole..
---Current rise rate damage. The characteristic as same as the current damage, and its position is near the control pole.
---The edge damage. It happen at the outer chamfer of the power supply dimmer chip, with small smooth holes. Use a magnifying glass to see scratches on the chamfer surface.