Led Driver 0-10V 12V 60W 5A Dimmable Led Power Supply Driver Transformer
As a fact of that,dimmable led transformer have a 0/1-10V to PWM dimming driver which has solved the compatible problem of fluorescent dimming system and LED illumination. LED lamps can be controlled by many traditional intelligent dimming systems.such as Lutron 0-10V dimmer 220V.
Feature |
|
·Output constant voltage type ·Input voltage Range 100-265VAC ·Built-in PFC function, PF>0.90 ·Efficiency> 88% ·Protections:short circuit/over current/over voltage/over temperature ·Cooling by free air convection ·IP67 design for indoor or outdoor installation . ·Dimming function:0-10V/ 1-10V/ 10V PWM or potentiometer. ·Suitable for LED lighting and moving sign applications ·Compliance to worldwide safety regulations for lighting ·Suitable for dry/damp/wet locations
·5 years warranty
|
Specification
Model
SMT-012-060VD
SMT-024-060VD
Output
DC Voltage
12V
24V
Voltage Accuracy
±0.5V
Rated current
0~5.0A
0~2.5A
Rated power
60W
Input
Voltage Range
AC100~130V / AC170~265V
Frequency Range
47~63HZ
Power Factor ( Typ.)
PF≧0.90/110V; PF≧0.90/220V
Full Load Efficiency(Typ.)
>88%
>88%
AC Current(Typ.)
0.689A@110VAC
0.344A@220VAC
Leakage current
﹤0.66mA/110VAC ; ﹤0.7mA/220VAC
Protection
Short Circuit
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over voltage
≦280VAC
Over temperature
100℃±10℃ shut down o/p voltage, re-power on to recover
Environment
Working TEMP.
-40~+60℃
Working Humidity
20~95%RH,non-condensing
Storage TEM.,Humidity
-40~+80℃,10~95%RH
TEMP.coefficient
±0.03%/℃(0~50℃)
Vibration
10~500Hz,5G 12min./1 cycle,period for 72min.each along X,Y,Z axes
Safety&EMC
Safety standards
EN61347-1 EN61347-2-13.
Withstand voltage
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
Isolation resistance
I/P-O/P I/P-FG O/P-FG:100MΩ/500VDC/25℃/70%RH
EMC EMISSION
Compliance toEN55015,EN61000-3-2 (≧50%load)
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11,EN61547,A light industry level
Others
Weight
1.1Kg
Size
200*68.5*45mm(L*W*H)
packing
329*279*176mm/10pcs /CTN 245*80*58mm for inner box
Notes
1. All parameters NOT specially mentioned are measured at 110V/220VAC input , rated load
and 25℃ of ambient temperature.
2. Ripple& noise are measured at 20MHz of bandwidth by using a 12”twisted pair-wire
terminated with a 0.1uf &47uf parallel capacitor.
3. Tolerance:includes set us tolerance,line regulation and load regulation .
Meachanical Specification
Input Rubber H03VV-F 3G *0.75㎡,the green/yellow cable connect with (FG),Brown with AC (L),Blue with AC
Signal Rubber H03VV-F 2G*0.75㎡,Blue is(DIM+),White is(DIM-)
Output Rubber H03VV-F 2G*0.75㎡,Red is output(V+),Black is output(V-)
Diagram reference