waterproof ip67 constant voltage dimmable 12v 500W led driver for led light
Smartspower new upgraded 500W TRIAC dimmable led power supply with fully protected aluminum housing. Dimming mode can be switched between PWM and VR mode. Dimming range is between 0.1%-100% with ultra-deep dimming. Comply with global safety lighting regulations.
Specification
Model | SMT-12500-VT-A | SMT-24500-VT-A | SMT-36500-VT-A | SMT-48500-VT-A | |
Certificate | UL / FCC / Type HL/ Class P / SELV / CE / RoHS / REACH | ||||
Output | DC Voltage | 12V | 24V | 36V | 48V |
Voltage Tolerance | ±1.5% | ±1.5% | ±1% | ±1% | |
Voltage Regulation | ≤0.5% | ||||
Rated current | 41.67A | 20.83A | 13.89A | 10.42A | |
Rated power | 500W | ||||
Load Regulation | ±1% | ||||
Input | Voltage Range | 110-277VAC | |||
Frequency Range | 47 - 63Hz | ||||
Power Factor @ full load | >0.95 | ||||
Efficiency @ full load |
90%@120VAC 92.5%@277VAC |
90.2%@120VAC 93%@277VAC |
90.2%@120VAC 93%@277VAC |
90.2%@120VAC; 93%@277VAC |
|
AC Current (Max.) | 5.1A | ||||
THD(Typ.)@full load | <20%@120VAC &277VAC | ||||
Inrush Current (Typ.) | 52A,810us@50%Ipeak110Vac;76A,148us@50%Ipeak277Vac | ||||
Leakage current | <0.5mA | ||||
Protection | Short Circuit | Hiccup mode, automatically recovers after an exception is removed | |||
Over Load | ≤120%,hiccup mode, automatically recovers after an exception is removed | ||||
Over Temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling | ||||
Environment | Working TEMP | -40~+60℃ (see below derating curve) | |||
Working Humidity | 20 -95%RH non-condensing | ||||
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | ||||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | ||||
Ambient TEMP. | 45℃ | ||||
Case TEMP. | 90℃ | ||||
Vibration | 10~500Hz, 5G 10min./1 cycle, period for 60min. each along X,Y,Z axes | ||||
Safety & EMC | Safety standards | UL8750 (US) | |||
EMC Emission | FCC Part 15 Subpart B; ANSI C63.4a-2017 | ||||
EMC Immunity | Conform to EN61000-4-2,3,4,5,6,11 EN61547 | ||||
Withstand voltage | I/P-O/P:1.8KVAC I/P-FG:1.8KVac O/P-FG:1.8KVac | ||||
Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70%RH | ||||
Stroboscopic test standards | Conform to IEEE 1789 no flicker | ||||
Lightning surge | Different mode: 2KV,Common mode: 4KV | ||||
Others | Net Weight | 2.58Kg | |||
Dimension | 280*140.2*48.5mm(L*W*H) | ||||
Packing | 342*285*170mm 5pcs /CTN | ||||
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input,rated load and 25℃ of ambient temperature. | ||||
2. Under low input voltage, derating output is required to ensure a long life. | |||||
3. Regarding LED driver load types where the driver meets the harmonic emissions requirements of ANSl C82.77-10. |
Mechanical Specification
American wire gauge | |
DT601 | |
Input wire | Black(L)White(N)Green(G)(3*18AWG) |
Output wire(12V) |
Red(V+) Black(V-)(2*14AWG) Red(V+) Black(V-)(2*14AWG) Red(V+) Black(V-)(2*14AWG) |
Output wire(24V) |
Red(V+) Black(V-)(2*14AWG) Red(V+) Black(V-)(2*14AWG) |
Output wire(36V&48V) | Red(V+) Black(V-)(2*14AWG) |
Mode switch wire |
Blue&White/Yellow&Grey(2*18AWG) Connects Blue&White/Yellow&Grey:PWM mode Disconnects Blue&White/Yellow&Grey:VR mode. |
Remarks:Please make sure your connect these correctly otherwise your product will not function correctly and could be damaged |
MCB recommendation:
When the input voltage is 120Vac,the number of LED Driver matched by circuit breakers is as follows: | ||
MCB Type | Level | The number of LED Driver |
C type | 10A | 1 |
13A | 2 | |
16A | 2 | |
20A | 3 | |
25A | 4 | |
When the input voltage is 277Vac,the number of LED Driver matched by circuit breakers is as follows: | ||
MCB Type | Level | The number of LED Driver |
C type | 10A | 2 |
13A | 3 | |
16A | 4 | |
20A | 5 | |
25A | 6 |
Note:
1. The above quantities of the led drivers connected on the Type C is recommended base on the maximum ambient temperature is 50 ℃.
2. The breaker should be selected according to the input rated voltage, input rated current, ambient temperature, and trip characteristic curve.
Dimming Operation
Using one dimming ---TRIAC/Phase cut dimming
1.The Pulse-Width Modulation (PWM) of output voltage can be adjusted through input terminal of the AC phase line(L) by connection
a phase /Triac dimmer or lighting system.
2.Working with forward phase /leading edge, MLV and Reverse phase /trailing edge, ELV, TRIAC dimmers or light system.
3.Min. loading is about 20%
4.Please try to use dimmers with power at least 1.5 times as the output power of the driver.
Related Products
Ultra-thin size triac & 0 10v dimmable 30W LED driver plastic shell design, waterproof level ip20. Suitable for installation and use in indoor small space lighting projects. Can be used with cabinet lights to achieve smooth flicker-free dimming.
Model: SMT-012-030VTDSP Input Voltage: 100-277vac
Dimming Mode: triac & 0 10v dimmable
|