triac dimmable constant current LED driver 700ma 900ma 40w
If you are just using the constant current LED lighting driver to power the led lighting, it doesn't matter which one you choose, but the 900ma constant current triac dimmable led driver look very clean for your constant current type LED.
Prooduct details
Specification Sheet
Model |
SMT-50-0700CTH |
SMT-45-0900CTH |
SMT-40-1050CTH |
SMT-28-1400CTH |
|
Output |
DC Current |
700mA |
900mA |
1050mA |
1400mA |
Current Accuracy |
±5% |
||||
Voltage Range |
38-50V |
33-45V |
28-40V |
16-28V |
|
Rated power |
40W |
40W |
40W |
40W |
|
Input |
Voltage Range |
180~250VAC |
|||
Frequency Range |
47~63HZ |
||||
Power Factor (Typ.) |
PF≧0.93/110V ; PF≧0.95/220V ; PF≧0.94/250V |
||||
Full Load Efficiency(Typ.) |
>85% |
>85% |
>85% |
>85% |
|
AC Current(Typ.) |
0.14A/110VAC 0.12 A/220VAC 0.01A/250VAC |
||||
Leakage current |
<0.27mA/110VAC; ﹤0.25mA/220VAC |
||||
Protection |
Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed. |
|||
Over voltage |
≦270VAC |
||||
Environment |
Working TEMP. |
-40~+60℃ |
|||
Working Humidity |
20~90%RH,non-condensing |
||||
Storage TEM.,Humidity |
-40~+80℃,10~95%RH |
||||
TEMP.coefficient |
±0.03%/℃(0~50℃) |
||||
Vibration |
10~500Hz,2G 10min./1 cycle,period for 60min. each along X,Y,Z axes |
||||
Safety&EMC |
Safety standards |
EN-60950-1, EN-61347-1-2 |
|||
Withstand voltage |
I/P-O/P:3.75KVAC |
||||
Isolation resistance |
I/P-O/P:100MΩ/500VDC/25℃/70%RH |
||||
EMC EMISSION |
Compliance toEN55015,EN61000-3-2 (≧50%load) |
||||
EMC IMMUNITY |
Compliance to EN55015,EN61000-4-2,3,4,5,6,8,11,A light industry level (surge4KV) |
||||
Others |
Weight |
0.34Kg/pcs |
|||
Size |
110*45*26mm (L*W*H) |
||||
packing |
290*275*190mm |
||||
Notes |
1. All parameters NOT specially mentioned are measured at 110V/230VAC input , rated load and 25℃of ambient temperature. 2. Ripple& noise are measured at 20MHz of bandwidth by using a 12”twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor. 3. Tolerance:includes set us tolerance,line regulation and load regulation . |
Simple Connection Diagram
FAQ
1. What is class 2 standard?
Answer: the requirements of class 2 are :1. less than or equal to 5A 2. less than 100w. And should satisfied with these two conditions at the same time.
2.Can we make the 120w 150w 200w 250w constant volatge led drivers into one output?
Answer: Yes.
3. If all dimmable LED drivers we ordered will provide more than 12 or 24 volts? As our some of LED lighting 's voltage is more than 24VDC a bit .
Answer: ±0.5% is the acceptable margin of error for both 12v dc and 24vdc led drivers.