Outdoor led supply 24 volt led power supply 1a 2a 30w 60w dimmable led transformer with Class 2 UL certified
As a fact of that, developed a new 0/1-10V to PWM dimming driver which has solved the compatible problem of fluorescent dimming system and LED illumination.With the dimmer of LEVITON TBL03, the effect of smooth dimming can be achieved,power led supply can be controlled by many traditional intelligent dimming systems.
Feature
·Output constant voltage
·Input voltage range 100-277VAC
·UL, cUL listed, Class 2, Class P standard
·Built-in PFC function / Efficiency > 86% / PF> 0.99
·Dimming range: 0~100%
·Protections:short circuit/over voltage/over heat
·IP67 design for indoor dry,wet or damp environment installations
·Cooling by free air convection
·0-10V dimming: 0-10V/1-10V/Potentiometer/10V PWM 4 in 1
·Full protection aluminum housing, for dry, damp, wet location
·Strong compatibility, flicker-free dimming
·Suitable for LED lighting and moving sign applications Class 2, Class P,Type HL standard
·Compliance to worldwide safety regulations for lighting 30W,36W,60W,96W,100W available
·7 years warranty
Specification
model
SMT-012-060VDSW
SMT-024-060VDSW
Output
DC Voltage
12VDC
24VDC
Voltage Accuracy
±5%
±5%
Rated current
5.0Amp
2.5Amp
Rated power
60W
60W
Voltage Regulation
±0.5%
Load Regulation
±1%
±1%
Input
Voltage Range
100-277VAC
Frequency Range
47~63HZ
Power Factor ( Typ.)
0.99@120VAC 0.95@277VAC
THD(Typ. ) @ full load
<10%@120VAC <15%@277VAC
Full Load Efficiency(Typ.)
84%@120VAC ,86%@277VAC
83%@120VAC ,85%@277VAC
AC Current(Typ.)
0.9A
Inrush Current(Typ.)
11A,50%,1ms@120VAC; 27A,50%,960us@277V
Leakage current
<0.5mA
Protection
Short Circuit
Hiccup mode, recovers automatically after fault condition
is removed.
Over Loading
≤120% shut down o/p voltage, re-power on to recover
Over temperature
100℃±10℃ shut down o/p voltage, automatically recover after cooling.
Environment
Working TEMP.
-40~+60℃
Working Humidity
20~95%RH,non-condensing
Storage TEM.,Humidity
-40~+80℃,10~95%RH
TEMP.coefficient
±0.03%/℃(0~50℃)
Vibration
10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes
Safety&EMC
Safety standards
UL8750 +UL 1310, CAN/CSA-C22.2 No.250.13
Withstand voltage
I/P-O/P:1.88KVac
Isolation resistance
I/P-O/P:100MΩ/500VDC/25℃/70%RH
EMC EMISSION
FCC 47 CFR Part 15 ,Subpart B
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,,11, ,
Alight industry level
Others
Weight
0.45Kg
Size
300*32*20mm (L*W*H)
packing
330*270*160mm/ 30pcs /CTN
Notes
1. All parameters NOT specially mentioned are measured at 110VAC, 277VAC input ,
Rated load and 25℃of ambient temperature.
2. Tolerance:includes set us tolerance,line regulation and load regulation .
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again.
label
Mechanical Specification
Derating Curve
Connecting Diagram