dimmable constant voltage led strip light driver power supply 60w 24v for led lighting
Constant voltage 60W 0 10v dimmable led power supply Full plastic protective shell design, waterproof level ip20. UL certification, in line with global safety lighting regulations, mainly sold to North America
Specification
Model | SMT-12060-VD-P | SMT-24060-VD-P | SMT-48060-VD-P | |
Certificate | UL / cUL / FCC / Class P / Class 2 | |||
Output | DC Voltage | 12V | 24V | 48V |
Voltage Tolerance | ±5% | ±2.5% | ±1.25% | |
Voltage Regulation | ≤0.5% | ≤0.5% | ≤0.5% | |
Load Regulation | ≤2% | ≤1% | ≤1% | |
Rated current | 5A | 2.5A | 1.25A | |
Rated power | 60W | |||
Voltage Ripple | 500mVp-p | 450mVp-p | 450mVp-p | |
Overshoot voltage | <7%(full load) | <5%(full load) | <5%(full load) | |
Output volt Adjustment | 12-13V | 24-26V | 48-50V | |
Output mode selection | The DIP switch in the "ON" position represents the PWM (Pulse - Width Modulation) mode, and in the "1" position represents the VR (Modulation of DC Voltage) mode. | |||
Switching the output mode requires the power to be cut off for 3 seconds and then powered on again for the mode switching to take effect. | ||||
Input | Voltage Range | 100-277VAC | ||
Frequency Range | 47 - 63Hz | |||
Power Factor (Typ.) @ full load |
>0.98@120VAC >0.97@277VAC |
>0.98@120VAC >0.97@277VAC |
>0.98@120VAC >0.97@277VAC |
|
THD(Typ. ) @ full load | <15%@120V <15%@277V | |||
Efficiency(Typ.) @ full load |
≥84%@120VAC ≥85.5%@277VAC |
≥84%@120VAC ≥86%@277VAC |
≥85%@120VAC ≥87%@277VAC |
|
AC Current (Max.) | ≤0.75A @120VAC ≤0.3A@277VAC | |||
Standby power | ≤0.5W | |||
Inrush Current (Typ.) | 31.6A,152us@50%Ipeak 120VAC 76.8A,156us@50%Ipeak 277VAC | |||
Leakage current | <0.5mA | |||
Protection | Short Circuit | Hiccup mode, can be automatically restored after abnormal removal | ||
Over Load | ≥120%,Constant - Current Mode, automatic recovery after exception | |||
Over temperature | When the ambient temperature exceeds 55℃ ±5℃, the output is turned off | |||
Environment | Working TEMP. | -40~+40℃ (see below derating curve) | ||
Working Humidity | 20 - 90%RH non-condensing | |||
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | |||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | |||
Vibration | 10 ~ 500Hz, 2G 12 minutes/cycle, X Y Z axis 72 minutes each | |||
Safety & EMC | Safety standards | UL8750 CAN/CSA-C22.2 No.250.13 | ||
Withstand voltage | I/P-O/P:1.88KVAC | |||
Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70% RH | |||
Surge Immunity Test | AC Power Line:Differential Mode 2KV | |||
EMC Immunity | FCC/ICES do not request this test | |||
EMC Emission | FCC Part15 Subpart B;ANSI C63.4:2017;ICES-005 Issue 5 | |||
Others | Net Weight | 0.35KG | ||
Dimension | 178*61.1*24mm(L*W*H) | |||
Packing | 290*215*140mm 20 pcs / CTN | |||
Notes | 1. All parameters NOT specially mentioned are measured at 120VAC input, rated load and 25℃of ambient temperature. | |||
2. Tolerance: includes set up tolerance and load regulation . | ||||
3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | ||||
4. Default states: The output mode is PWM output by default. The dimming curve is a gamma2.2 curve. | ||||
5. Regarding LED driver load types where the driver meets the harmonic emissions requirements of ANSI C82.77-10. |
Mechanical Specification
American wire gauge | |
SD8 | |
Input wire | DG128-3P |
Output wire | DG128-2P |
Dimming wire | DG128-2P |
MCB recommendation:
When the input voltage is 120Vac,the number of LED Driver matched by circuit breakers is as follows: | ||
MCB Type | Level | The number of LED Driver |
C type | 10A | 9 |
13A | 11 | |
16A | 14 | |
20A | 18 | |
25A | 23 | |
When the input voltage is 277Vac,the number of LED Driver matched by circuit breakers is as follows: | ||
MCB Type | Level | The number of LED Driver |
C type | 10A | 24 |
13A | 32 | |
16A | 40 | |
20A | 50 | |
25A | 62 |
Warm tips:
1. Recommended Max. Carrying Current (A) = wire diameter(mm²) x 10A/mm ²
For example: 1mm ² output cable, Recommended Max. Carrying Current (A) = 1mm ² x 10A/mm ²=10A
2. Any other requests for cable, we can customized.
Dimming Operation
Using one dimming ---0-10/ 1-10V/ 10V PWM/ Potentiometer dimming

Related Products
Constant voltage 60W 12V 0 10V dimmable led power supply integrated with junction box. Metal shell design, good heat dissipation, suitable for indoor led smart lighting project installation, 7 years warranty
Model: SMT-012-060VDH Input Voltage: 100-277vac
Dimming Mode: 0 10v dimmable
|